Energy consumption

Thanks to their dual-drive concept and very small displacement volume, our units are highly energy-efficient and compare favorably with other drive systems, such as electric drives.

Commercially available pneumatic screwdrivers consume between 120 l/min and 300 l/min. This is around ten times the air consumption of our TG units. The calculator below allows you to determine the energy consumption of our TG units as a function of stroke frequency.

For the TG1000 and TG1500, the optimum conveying speed ranges from 3.6 m/min (= 120 strokes/min) to 6.6 m/min (= 220 strokes/min). The higher-performance TG2000 and TG3000 reach a maximum conveying speed of 5.4 m/min (= 180 strokes/min).

At theoretically higher stroke rates, the physical operating principle of the linear conveyor ceases to function effectively.

As the calculation examples below show, our pneumatic parts conveyors are not energy-intensive; they are highly efficient in their energy use.

At stroke rate: 100
Conveying speed: 3,0 m/min

Unit
type
Load
kg
Consumption
l/min
Consumption
m³/h
Pressure
bar
Power
kW/h
Power
kW/year
Electricity cost
year / euro (*)
TG1000 15 11,30 0,68 4 0,05 108,52 20,62
TG1500 20 15,79 0,95 5 0,08 151,61 28,81
TG2000 30 21,27 1,28 4 0,10 204,23 38,80
TG3000 60 32,74 1,96 4 0,16 314,35 59,73



(*) Calculation based on specific performance values of modern compressor systems according to ISO 2017 at a rated motor output of 450 kW. The electricity price used is EUR 0.19/kWh. The consumption values were calculated using practical reference values. Actual values may vary depending on the production environment.